Interventional Cardiology
VIVO ISAR®
- Polymer-free sirolimus – eluting stent
- Cobalt chromium platform
- Microporous stent surface
- Abluminal coating
- Drug release to targeted site
- Shellac resin top coat and prevents destruction of drug during expansion
- 10 year – clinical efficacy and safety data
YUKON® CHOICE PC
- Sirolimus – eluting stent
- Biodegradable Polymer DES
- Low profile Ø2.5 mm
- Cobalt Chromium Coronary Stent System
- Microporous stent surface
- 10 year clinical efficacy and safety data
- Sirolimus – eluting stent
- 2 connector design for added flexibility and side branch
- Biodegradable Polymer DES (PLA)
- Abluminal coating
- Low profile Ø2.5 mm
- Stainless steel platform
- Microporous stent surface
- Flexible tip for crossability & trackability
- Next Generation PTCA Dilatation Catheter Cathy N° 4
- Proximal shaft diameter – 1.9 Fr
- Distal shaft diameter – 2.7 Fr
- Balloon crossing profile – 0.64 mm
- Manoeuvrable, pushable, flexible
EVEREST HYDROPHILIC WORKHORSE BALLOON
- Low profile
- Gradual taper
- Flexible performance
- Kink resistant
PROTÉGÉ DRUG ELUTING BALLOONS PROTÉGÉ NC DRUG ELUTING BALLOONS
- Paclitaxel – coated balloon
- Hydrophilic coating
- Wing seal technology
- Paclitaxel delivery within 30 seconds
- No excipient
CTO SUMMIT CTO CATHETER
- Optimized new lumen materials combine flexibility with required push stiffness
- Low inflation time
- Rated burst pressure 15 ATM
- Tight tip track over the guidewire
- Tip entry profile 0.016″ (0.40mm)
ANGIOGRAPHY CATHETER POINTER DIAGNOSTIC CATHETER
- Low resistance due to unique hydrodynamic surface
- Available in 3 sizes / 4 Fr – 6 Fr
- 5Fr catheter has the largest inner lumen on the market
- Superior kink resistance and 1-to-1 torque
- Atraumatic soft tip
GUIDING CATHETER PRIMUM GUIDING CATHETER
- Low resistance due to hydrophilic coating
- 1:1 torque control
- Excellent shape retention
- French size 5Fr – 8Fr
HEMOSTASIS VALVE (Y Connector)
- Unique push-click design – Minimizes blood loss effectively – One-handed operation – Complex PCI procedures
- Ergonomic knob design – Screw thread surface offers better control Large internal diameter facilitates insertion of instruments (2.7±0.1)
- Max. Pressure: 58 psi (Internal standard 180 psi)
- Extension tube optional
BALLOON IN-DEFLATION DEVICE
- Maximum pressure of 30atm
- 20ml clear syringe barrel with smooth moving plunger
- Selok® technology patent – self-locking mechanism for easy locking and Gradual or rapid pressure release
- Ergonomic handle
- Precision manometer
- Optional 3-way stopcock with “ON” or “OFF” handle
BOOSTING CATHETER
- Proprietary atraumatic tip design
- Hydrophilic coated distal tube
- Large internal passageways
- Expanded clinical indications, including intraprocedural fluid injection for selective contrast injection
- Working length of 150cm suitable for coronary and peripheral interventions